HQL LED PRO

Choose your product version

Overview HQL LED PRO

Product description Base (standard designation) Nominal wattage Nominal voltage Nominal lamp life time Nominal luminous flux
HQL LED 1800 lm 16 W/2700K E27 E27 16.00W 220…240V 50000h 1800lm
HQL LED 2000 lm 16 W/4000K E27 E27 16.00W 220…240V 50000h 2000lm
HQL LED 2700 lm 23 W/2700K E27 E27 23.00W 220…240V 50000h 2700lm
HQL LED 3000 lm 23 W/4000K E27 E27 23.00W 220…240V 50000h 3000lm
HQL LED 3600 lm 30 W/2700K E27 E27 30.00W 220…240V 50000h 3600lm
HQL LED 4000 lm 30 W/4000K E27 E27 30.00W 220…240V 50000h 4000lm
HQL LED 5400 lm 46 W/2700K E27 E27 46.00W 220…240V 50000h 5400lm
HQL LED 5400 lm 46 W/2700K E40 E40 46.00W 220…240V 50000h 5400lm
HQL LED 6000 lm 46 W/4000K E27 E27 46.00W 220…240V 50000h 6000lm
HQL LED 6000 lm 46 W/4000K E40 E40 46.00W 220…240V 50000h 6000lm
HQL LED 11700 lm 95 W/2700K E40 E40 95.00W 220…240V 50000h 11700lm
HQL LED 13000 lm 95 W/4000K E40 E40 95.00W 220…240V 50000h 13000lm
 

HQL LED 4000 lm 30 W/4000K E27

Product benefits
  • Saves up to 78 % energy when used as replacement for mercury vapor lamps (HQL)
  • Low maintenance costs thanks to long lifetime
  • Instant 100 % light, no warm-up time

Product details

Electrical data

Rated wattage 30.00 W
Nominal wattage 30.00 W
Nominal voltage 220…240 V
Max. lamp no. on circuit break. 10 A (B) 42
Max. lamp no. on circuit break. B10 A - CCG without compensation 42
Max. lamp no. on circuit break. B16 A - CCG without compensation 68
Max. lamp no. on circuit break. 16 A (B) 68
Operating frequency 50/60 Hz
Inrush current 3.60 A
Power factor λ 0.90

Photometrical data

Nominal luminous flux 4000 lm
Rated luminous flux 4000 lm
Lumen main.fact.at end of nom.life time 0.70
Light color (designation) Cool White
Color temperature 4000 K
Luminous flux 4000 lm
Color rendering index Ra ≥80
Standard deviation of color matching ≤6 sdcm
Rated color temperature 4000 K
Color rendering index Ra ≥80

Light technical data

Warm-up time (60 %) < 0.50 s
Beam angle 360 °
Starting time < 0.5 s

Dimensions & weight

Overall length 170.0 mm
Diameter 75.0 mm
Outer bulb -
Length 170.0 mm

Temperatures & operating conditions

Ambient temperature range -20…+60 °C
Maximum temperature at tc test point 92 °C

Lifespan

Nominal lamp life time 50000 h
Rated lamp life time 50000 h
Number of switching cycles 100000
Lumen maintenance at end of service life 0.70

Additional product data

Base (standard designation) E27
Mercury content 0.0 mg
Mercury-free Yes
Design / version Clear
Show WEEE picto Yes

Capabilities

Dimmable No

Certificates & standards

Photobiological safety group EN62778 RG1
Energy efficiency class A++
Energy consumption 30 kWh/1000h

Country-specific categorizations

Order reference HQLLED4000 30W/
Product code Packaging unit
Piece / unit
Dimensions in h x w x l Gross weight Volume
4058075124820 FS
1
82mm x 82mm x 201mm 543.00g 1.35dm³
4058075124837 VS
6
255mm x 175mm x 226mm 3514.00g 10.09dm³
EAN SEG number EFO number ELDAS number
4058075124820 8294048 3720128 941800130
Product benefits
  • Saves up to 78 % energy when used as replacement for mercury vapor lamps (HQL)
  • Low maintenance costs thanks to long lifetime
  • Instant 100 % light, no warm-up time
Areas of application
  • Streets
  • Area lighting
  • Pedestrian zones
  • Parks
  • Outdoor applications only in suitable luminaires
Product features
  • Replacement for HQL: Suitable for operation with conventional control gear (CCG) for HQL or 230 V mains
  • Replacement for other HID: Suitable for operation with line voltage without control gear
  • Power factor: 0.9
  • Type of protection: IP65
  • High surge protection: up to 4 kV (L-N)

Safety advice
The bulb may be larger and heavier than the replaced bulb. Before installation it must be checked, if the luminaire and especially the holder is capable of carrying the weight of the lamp. If possible, please install the safety rope included in the package containing the lamp for the types 46 W and 95 W.
Not suitable for operation with ignitors
Operation on the capacitor can lead to a reduction of the power factor of the system.
When installed horizontally, the tc point of the lamp is located on the top side of the lamp.
Use in tight luminaires and luminaires with tight reflectors not recommended.